				Pilt on illustreeriv
			 
 
 | 
Room Temperature Sensor ThermasGard® RTM1-Modbus-P-BD1, on-wall, temp., relative humidity, dew point, setpoint potentiometer, humidity sensor w. integrated temperature sensor, 0..50°C, 24VAC/15..36VDC, IP30, calibratable Kood:
		1101-42A6-0001-005
 
 
Hind  
€ 159,70
 /tk
 
(€ 198,03 /tk KM-ga)
 
 
				Tootja
			: 
| 
 Saadavus:
			 
14 päeva 
 | 
 Kaal:  
0.03 kg/tk 
 | 
 | 
 | 
 
 
 | 
 | 
 
 
 | 
 
 
	
	
Room operating temperature sensor THERMASGARD® RTM1-Modbus-P-BD1, on-wall, temp.˄relative humidity˄dew point˄setpoint potentiometer, humidity sensor w. integrated temperature sensor, 0..50°C, 24VAC/15..36VDC, IP30, calibratable, S+S Regeltechnik
    
        
		
		
		Calibratable room temperature measuring transducer THERMASGARD® RTM1 Modbus With Modbus connection, with ⁄ without optional display for displaying the actual temperature, in an elegant enclosure made of plastic, with snap-on lid, base with 4-hole attachment, for installation on vertically or horizontally installed in-wall flush boxes, with predetermined breaking point for on-wall cable entry.
		 
		 
		
The calibratable room operating sensor measures the temperature of non-aggressive gases, particularly air. In this case, a setpoint potentiometer is available as an operating element. Optional devices with LCD displays for displaying readings are available for temperature/humidity/dew point or setpoint readings. The displays (LCD) and the retrieval of measurement and control values are triggered via the Modbus interface.
		 | 
		 
		
 
 	 | 
 	 
 
	
	
    
        
           
		
           
            
            
                
                    
                        
                        
						Technical data:
                         | 
                     
                    
                        | 
						Power supply: | 
                        
						24 V AC ±20%  
						15...36 V DC | 
                     
					
					
                    | 
						Power consumption: | 
                        	< 2.2 VA / 24 V AC 
													< 1.1 W / 24 V DC | 
                     
					
					
                    
					| 
						Temperature-measuring range: | 
                        0 ... 50 °C | 
                     
					
					
						Deviation, temperature: | 
                        ±0.2 K, ±0.4 K@ 25°C | 
                    
					
					
                    | 
						Storage temperature: | 
                        -30 ... 80 °C | 
                     
					
                    | 
						Enclosure dimensions: | 
                        85 x 85 x 27 mm (Baldur 1) | 
                     
					
					| 
						Electrical connection: | 