|  | 
| 
 | 
 
|  |  
| 
| 
  
				Pilt on illustreeriv
			 | Contact Insert HC-B 10-I-CT-F, 1pcs/pck, Phoenix Kood:
		1648225
Hind (indikatiivne) 
€ 12,40
 /tk
(€ 15,38 /tk KM-ga)
 
				Tootja
			: 
| Saadavus:
			 21 päeva | Kaal:  0.0484 kg/tk | Maht:  0 m3/tk |  |  |  |  |  
| 
| 
| Contact Insert HC-B 10-I-CT-F, 1pcs/pck, PhoenixGeneral
| Note | For HEAVYCON ADVANCE and HEAVYCON housing of B10 type, crimp contacts CK 2,5-ED (crimp contacts not included in the scope of supply). |  
|  | Connectors may be operated only when there is no load/voltage. |  
| Connection method | Crimp connection |  
| Torque | 0.8 Nm ... 1.2 Nm (PE connection) |  
|  | 0.5 Nm ... 0.8 Nm (Mounting screws for mounting in the HEAVYCON housing) |  
| Number of connections per position | 1 |  
| Degree of pollution | 3 |  
| Overvoltage category | III |  
| Number of positions | 10+PE |  
| Insertion/withdrawal cycles | ≥ 500 |  
| Size | B10 |  
| Contact numbering | 1 - 10 |  
| Conductor cross section | 0.5 mm² ... 4 mm² |  
| Connection cross section AWG | 20 ... 12 |  
| Stripping length of the individual wire | 7.5 mm |  
| Assembly instructions | To ensure correct use, installation in housing with IP54 protection or better is required |  
| Connection | Remove the crimp contact using a screwdriver. The opening for the screwdriver is next to the opening where the conductor is inserted. |  Ambient conditions
| Degree of protection (IP) | IP20 |  
| Ambient temperature (operation) | -40 °C ... 125 °C (including heating up of contacts) |  Material data
| Contact material | Copper alloy |  
| Contact surface material | Ag (alternatively Au) |  
| Contact carrier material | PA |  
| Standards/regulations | PA: Fire protection in rail vehicles - requirement sets R22 and R23 acc. to DIN EN 45545-2 (Risk level HL1 - HL2) |  
|  | PA: Fire protection in rail vehicles - requirement set R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3) |  Electrical characteristics
| Rated voltage (III/3) | 500 V |  
| Rated surge voltage | 6 kV |  
| Rated current | 16 A |  Standards and Regulations
| Connection in acc. with standard | CSA |  
| Constructional and testing regulations | DIN EN 61984 |  
|  | DIN EN 60664 |  
|  | IEC 60352 |  
| Flammability rating according to UL 94 | V0 |  
| Standards/regulations | acc. to DIN EN 45545-2 |  Environmental Product Compliance
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |  
|  | No hazardous substances above threshold values |  ECLASS
| ECLASS 10.0.1 | 27440205 |  
| ECLASS 11.0 | 27440205 |  
| ECLASS 4.0 | 27140800 |  
| ECLASS 4.1 | 27140800 |  
| ECLASS 5.0 | 27143400 |  
| ECLASS 5.1 | 27261200 |  
| ECLASS 6.0 | 27261200 |  
| ECLASS 7.0 | 27440205 |  
| ECLASS 9.0 | 27440205 |  ETIM
| ETIM 3.0 | EC000438 |  
| ETIM 4.0 | EC000438 |  
| ETIM 6.0 | EC000438 |  
| ETIM 7.0 | EC000438 |  UNSPSC
| UNSPSC 6.01 | 30211923 |  
| UNSPSC 7.0901 | 39121522 |  
| UNSPSC 11 | 39121522 |  
| UNSPSC 12.01 | 39121522 |  
| UNSPSC 13.2 | 39121522 |  
| UNSPSC 18.0 | 39121522 |  
| UNSPSC 19.0 | 39121522 |  
| UNSPSC 20.0 | 39121522 |  
| UNSPSC 21.0 | 39121522 |  |  
| 
| File description | File type | Download link |  
|  |  |  |  |  |  |  
  | 
| 
 |