General information |
Product type designation |
F-DQ 8x24VDC/2A PPM |
Firmware version |
|
● FW update possible |
Yes |
Product function |
● I&M data |
Yes; I&M0 to I&M3 |
Engineering with |
● STEP 7 TIA Portal configurable/integrated as of version |
V13 SP1 with HSP 0086 |
Operating mode |
● DQ |
Yes |
Supply voltage |
Type of supply voltage |
24 V DC |
Rated value (DC) |
24 V |
permissible range, lower limit (DC) |
19.2 V |
permissible range, upper limit (DC) |
28.8 V |
Reverse polarity protection |
Yes |
Input current |
Current consumption (rated value) |
110 mA; without load |
Output voltage |
Rated value (DC) |
24 V |
Power |
Power available from the backplane bus |
0.8 W |
Power loss |
Power loss, typ. |
11 W |
Address area |
Address space per module |
● Address space per module, max. |
6 byte |
Hardware configuration |
Automatic encoding |
Yes |
● Electronic coding element type F |
Yes |
Digital outputs |
Number of digital outputs |
8 |
Current-sinking |
Yes |
Current-sourcing |
Yes |
Short-circuit protection |
Yes |
Open-circuit detection |
Yes |
● Response threshold, typ. |
8 mA |
Overload protection |
Yes |
● Response threshold, typ. |
2.9 A |
Limitation of inductive shutdown voltage to |
PM-switching: -24 V + (-47 V), PP-switching: -24 V |
Switching capacity of the outputs |
● with resistive load, max. |
2 A |
● on lamp load, max. |
10 W |
Load resistance range |
● lower limit |
12 Ω |
● upper limit |
2 000 Ω |
Output voltage |
● for signal "1", min. |
24 V; L+ (-0.5 V) |
Output current |
● for signal "1" rated value |
2 A |
● for signal "0" residual current, max. |
0.5 mA; Current-sourcing, or current sourcing and sinking switches individually, current sinking: max. 1 mA |
Switching frequency |
● with resistive load, max. |
30 Hz |
● with inductive load, max. |
0.1 Hz |
● on lamp load, max. |
10 Hz |
Total current of the outputs |
● Current per channel, max. |
2 A |
Total current of the outputs (per module) |
horizontal installation |
— up to 40 °C, max. |
16 A |
— up to 60 °C, max. |
8 A |
vertical installation |
— up to 40 °C, max. |
8 A |
Cable length |
● shielded, max. |
1 000 m |
● unshielded, max. |
500 m |
Interrupts/diagnostics/status information |
Diagnostics function |
Yes |
Substitute values connectable |
No |
Alarms |
● Diagnostic alarm |
Yes |
Diagnostic messages |
● Monitoring the supply voltage |
Yes |
● Wire-break |
Yes |
● Short-circuit |
Yes |
● Group error |
Yes |
Diagnostics indication LED |
● RUN LED |
Yes; Green LED |
● ERROR LED |
Yes; Red LED |
● Monitoring of the supply voltage (PWR-LED) |
Yes |
● Channel status display |
Yes; Green LED |
● for channel diagnostics |
Yes; Red LED |
● for module diagnostics |
Yes; Red LED |
Potential separation |
Potential separation channels |
● between the channels |
No |
● between the channels and backplane bus |
Yes |
Isolation |
Isolation tested with |
707 V DC (type test) |
Standards, approvals, certificates |
Highest safety class achievable in safety mode |
● Performance level according to ISO 13849-1 |
PLe |
● SIL acc. to IEC 61508 |
SIL 3 |
Probability of failure (for service life of 20 years and repair time of 100 hours) |
— Low demand mode: PFDavg in accordance with SIL3 |
< 6.00E-05 |
— High demand/continuous mode: PFH in accordance with SIL3 |
< 2.00E-09 1/h |
Ambient conditions |
Ambient temperature during operation |
● horizontal installation, min. |
0 °C |
● horizontal installation, max. |
60 °C |
● vertical installation, min. |
0 °C |
● vertical installation, max. |
40 °C |
Dimensions |
Width |
35 mm |
Height |
147 mm |
Depth |
129 mm |
Weights |
Weight, approx. |
300 g |
last modified: |
11/10/2018 |