e-Elit - juhtiv
elektri- ja automaatikatarvikute
online hulgimüük
Klienditeenindus E-R 9-17
Helista: +372 622 9119
Est En
Elit shopping basket
Tooteid: Maksumus:
0
€ 0,00
    search
Logi sisse
Kasutajatunnus/e-post:

Parool:

Näita kõiki kategooriaid
Ei leidnud sobilikku toodet?
Head pakkumised!
Miniature Circuit Breaker DX³, 2C 4A 6/10kA
Miniature Circuit Breaker DX³, 2C 4A 6/10kA



Näita laos
Näita km-ga hindu
Sagedusmuundur E2100, 22kW 44A 3x 380..460VAC ±15%, 0.5..650Hz, overload 150% 60s, LED display, V/Hz, SVC, CLV, PMSM, ModBus, brake, EMC C3, frame E6
Pilt on illustreeriv
Sagedusmuundur E2100, 22kW 44A 3x 380..460VAC ±15%, 0.5..650Hz, overload 150% 60s, LED display, V/Hz, SVC, CLV, PMSM, ModBus, brake, EMC C3, frame E6
Kood: E2100-0220T3
Hind (indikatiivne)
€ 1 329,00  /tk
(€ 1 647,96 /tk KM-ga)
Tootja :
Saadavus:
7 päeva
Kaal:
0.1234 kg/tk
Kogus (tk):
Plus sign Minus sign
 

Overview
Frequency inverter series for induction motors ^permanent magnet synchronous motors, offering V/F, sensorless vector, closed-loop vector ^PMSM control for industrial applications.
Features
Motor power 0.2..400kW
Motor control V/F, SVC, VC, PMSM SVC
Autotuning Intelligent motor autotuning
Communication Modbus ^CAN
EMC filter Integrated C3 class
Process control Integrated PID control
Electrical Data
Input voltage, 1-phase 220..240VAC ±15%
Input voltage, 3-phase 220..240VAC ±15%
Input voltage, 3-phase 380..480VAC +10%/-15%
Rated frequency 50/60Hz
Output voltage 3-phase 0..input voltage
Output frequency 0.50..590.0Hz
Carrier frequency 800..16000Hz
Control Performance
Input frequency resolution Digital 0.01Hz, analog max. frequency x0.1%
Start torque 0.5Hz/150% SVC, 0Hz/180% VC
Speed-control scope 1:100 SVC, 1:1000 VC, 1:20 PMSM SVC
Steady speed precision ±0.5% SVC, ±0.02% VC
Torque control precision ±5%
Overload capacity 150% rated current, 60s
DC braking frequency 0.20..50.00Hz
DC braking time 0.00..30.00s
Jogging time 0.1..3000s
Operation Functions
Multi-stage speed 15-stage speed running
PID control Built-in process closed-loop control
Voltage regulation Automatic voltage regulation
Frequency setting Potentiometer, 0..5V, 0..10V, 0..20mA, keypad, terminal, communication
Start/stop control Terminal, keypad, communication
Protection
Input phase loss, output phase loss, input under-voltage, DC over-voltage, over-current, inverter overload, motor overload, current stall, over-temperature, external disturbance, under-load, pressure control, analog line disconnection, PG line disconnection, keypad disconnection, oPEn protection, STO, STO1.
Environment
Operating temperature -10..+50°C
Humidity Below 90%, no condensation
Vibration Below 0.5g
Altitude 1000m or below
Protection level IP20/NEMA1
 
 
Elit OÜ | e-post: elit@elit.ee | +372 622 9119 | 2021 ©


 
X
 