Pilt on illustreeriv
|
Uninterruptible Power Supply QUINT-UPS/ 24DC/ 24DC/20, Phoenix Kood:
2320238
Hind
€ 206,30
/tk
(€ 251,69 /tk KM-ga)
Tootja
:
Saadavus:
küsi tarneaega
|
Kaal:
0.8045 kg/tk
|
Maht:
0.0007 m3/tk
|
|
|
|
|
Uninterruptible Power Supply QUINT-UPS/ 24DC/ 24DC/20, PhoenixDimensions
Width
|
40 mm
|
Height
|
130 mm
|
Depth
|
125 mm
|
Width with alternative assembly
|
123 mm
|
Height with alternative assembly
|
130 mm
|
Depth with alternative assembly
|
43 mm
|
Installation distance right/left
|
5 mm / 5 mm
|
Installation distance top/bottom
|
50 mm / 50 mm
|
Ambient conditions
Degree of protection
|
IP20
|
Ambient temperature (operation)
|
-25 °C ... 70 °C
|
Ambient temperature (storage/transport)
|
-40 °C ... 85 °C
|
Max. permissible relative humidity (operation)
|
≤ 95 % (25 °C, non-condensing)
|
Climatic class
|
3K3 (in acc. with EN 60721)
|
Input data
Input voltage
|
24 V DC
|
Nominal input voltage
|
24 V DC
|
Input voltage range
|
18 V DC ... 30 V DC
|
Current consumption (maximum)
|
32.9 A (maximum, mains operation)
|
Current consumption (charging process)
|
6.9 A (Charging, mains operation)
|
Fixed backup threshold
|
≤ 22 V DC
|
Variable connect threshold
|
1 V/0.1 s
|
Output data (24 V DC mains operation)
Nominal output voltage
|
24 V DC
|
Output voltage range (depends on the input voltage)
|
18 V DC ... 30 V DC
|
Nominal output current (IN)
|
20 A (-25 °C ... 60 °C)
|
POWER BOOST (IBoost)
|
26 A (-25°C ... 40°C)
|
Selective Fuse Breaking (ISFB)
|
120 A (-25 °C ... 60 °C)
|
Output data (24 V DC battery operation)
Nominal output voltage
|
24 V DC
|
Output voltage range (depends on the input voltage)
|
19.2 V DC ... 27.6 V DC (UOUT = UBAT - 0,5 V DC)
|
Nominal output current (IN)
|
20 A (-25 °C ... 60 °C)
|
POWER BOOST (IBoost)
|
27 A (-25°C ... 40°C)
|
Selective Fuse Breaking (ISFB)
|
120 A (-25 °C ... 60 °C)
|
General output data
Efficiency
|
> 98 % (Mains operation, with charged energy storage)
|
General
IQ technology
|
Yes
|
Net weight
|
0.6 kg
|
Protection class
|
III
|
MTBF (IEC 61709, SN 29500)
|
> 500000 h (40 °C)
|
Mounting position
|
horizontal DIN rail NS 35, EN 60715
|
Assembly instructions
|
alignable: horizontal 5 mm, vertical 50 mm
|
Connection data, input
Connection method
|
Screw connection
|
Conductor cross section solid min.
|
0.2 mm²
|
Conductor cross section solid max.
|
6 mm²
|
Conductor cross section flexible min.
|
0.2 mm²
|
Conductor cross section flexible max.
|
4 mm²
|
Conductor cross section AWG min.
|
12
|
Conductor cross section AWG max.
|
10
|
Stripping length
|
8 mm
|
Screw thread
|
M4
|
Connection data, output
Connection method
|
Screw connection
|
Conductor cross section solid min.
|
0.2 mm²
|
Conductor cross section solid max.
|
6 mm²
|
Conductor cross section flexible min.
|
0.2 mm²
|
Conductor cross section flexible max.
|
4 mm²
|
Conductor cross section AWG min.
|
12
|
Conductor cross section AWG max.
|
10
|
Stripping length
|
8 mm
|
Screw thread
|
M4
|
Connection data for signaling
Conductor cross section solid min.
|
0.2 mm²
|
Conductor cross section solid max.
|
4 mm²
|
Conductor cross section flexible min.
|
0.2 mm²
|
Conductor cross section flexible max.
|
2.5 mm²
|
Conductor cross section AWG min.
|
24
|
Conductor cross section AWG max.
|
12
|
Screw thread
|
M4
|
Standards
EMC requirements for noise immunity
|
EN 61000-6-1
|
|
EN 61000-6-2
|
EMC requirements for noise emission
|
EN 61000-6-3
|
|
EN 61000-6-4
|
Standard - Electrical safety
|
EN 60950-1/VDE 0805 (SELV)
|
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations
|
EN 50178/VDE 0160 (PELV)
|
Rail applications
|
EN 50121-4
|
Conformance/approvals
UL approvals
|
UL Listed UL 508
|
|
UL/C-UL Recognized UL 60950-1
|
|
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
|
EMC data
Electromagnetic compatibility
|
Conformance with EMC Directive 2014/30/EU
|
Low Voltage Directive
|
Conformance with Low Voltage Directive 2014/35/EC
|
Electrostatic discharge
|
EN 61000-4-2
|
Contact discharge
|
8 kV (Test Level 4)
|
Discharge in air
|
15 kV (Test Level 4)
|
Electromagnetic HF field
|
EN 61000-4-3
|
Frequency range
|
80 MHz ... 1 GHz
|
Test field strength
|
20 V/m
|
Frequency range
|
1 GHz ... 3 GHz
|
Test field strength
|
10 V/m
|
Frequency range
|
2 GHz ... 3 GHz
|
Test field strength
|
3 V/m
|
Comments
|
Criterion A
|
Fast transients (burst)
|
EN 61000-4-4
|
Input
|
2 kV (Test Level 3 - asymmetrical)
|
Output
|
2 kV (Test Level 3 - asymmetrical)
|
Signal
|
2 kV (Test Level 4 - asymmetrical)
|
Comments
|
Criterion A
|
Surge voltage load (surge)
|
EN 61000-4-5
|
Input
|
1 kV (Test Level 2 - symmetrical)
|
|
2 kV (Test Level 3 - asymmetrical)
|
Output
|
1 kV (Test Level 2 - symmetrical)
|
|
2 kV (Test Level 3 - asymmetrical)
|
Signal
|
1 kV (Test Level 2 - asymmetrical)
|
Comments
|
Criterion A
|
Conducted interference
|
EN 61000-4-6
|
I/O/S
|
asymmetrical
|
Frequency range
|
0.15 MHz ... 80 MHz
|
Voltage
|
10 V (Test Level 3)
|
Comments
|
Criterion A
|
Criterion A
|
Normal operating behavior within the specified limits.
|
Criterion B
|
Temporary impairment to operational behavior that is corrected by the device itself.
|
Environmental Product Compliance
REACh SVHC
|
Lead 7439-92-1
|
China RoHS
|
Environmentally Friendly Use Period = 25;
|
|
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
|
ECLASS
ECLASS 10.0.1 |
27040705
|
ECLASS 11.0 |
27040705
|
ECLASS 4.0 |
27040600
|
ECLASS 4.1 |
27040600
|
ECLASS 5.0 |
27040600
|
ECLASS 5.1 |
27040600
|
ECLASS 6.0 |
27040600
|
ECLASS 7.0 |
27040603
|
ECLASS 9.0 |
27040705
|
ETIM
ETIM 3.0 |
EC001039
|
ETIM 4.0 |
EC000382
|
ETIM 6.0 |
EC000382
|
ETIM 7.0 |
EC000382
|
UNSPSC
UNSPSC 6.01 |
30211510
|
UNSPSC 7.0901 |
39121011
|
UNSPSC 11 |
39121011
|
UNSPSC 12.01 |
39121011
|
UNSPSC 13.2 |
39121011
|
UNSPSC 18.0 |
39121011
|
UNSPSC 19.0 |
39121011
|
UNSPSC 20.0 |
39121011
|
UNSPSC 21.0 |
39121011
|
|
File description
|
File type
|
Download link
|
|
|
|
|
|
|
|
|