Image is illustrative
|
Power Supply Unit QUINT-PS-100-240AC/24DC/ 5, Phoenix Code:
2938581
Price
€284.40
/pc
(€346.97 /pc with VAT)
Manufacturer
:
Availability:
21 days
|
Weight:
1.1726 kg/pc
|
Volume:
0.0009 m3/pc
|
|
|
|
|
Power Supply Unit QUINT-PS-100-240AC/24DC/ 5, PhoenixDimensions
Width
|
55 mm
|
Height
|
130 mm
|
Depth
|
125 mm
|
Width with alternative assembly
|
122 mm
|
Height with alternative assembly
|
130 mm
|
Depth with alternative assembly
|
58 mm
|
Ambient conditions
Degree of protection
|
IP20
|
Ambient temperature (operation)
|
-25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
|
Ambient temperature (storage/transport)
|
-40 °C ... 85 °C
|
Max. permissible relative humidity (operation)
|
95 % (at 25 °C, non-condensing)
|
Degree of pollution
|
2
|
Input data
Nominal input voltage range
|
100 V AC ... 240 V AC
|
Input voltage range
|
85 V AC ... 264 V AC
|
|
90 V DC ... 350 V DC
|
AC frequency range
|
45 Hz ... 65 Hz
|
Frequency range DC
|
0 Hz
|
Current consumption
|
approx. 1.6 A (120 V AC)
|
|
approx. 0.84 A (230 V AC)
|
Nominal power consumption
|
134 W
|
Inrush current
|
< 20 A (typical)
|
Mains buffering time
|
> 30 ms (120 V AC)
|
|
> 130 ms (230 V AC)
|
Input fuse
|
5 A (slow-blow, internal)
|
Recommended breaker for input protection
|
6 A ... 16 A (Characteristics B, C, D, K)
|
Type of protection
|
Transient surge protection
|
Protective circuit/component
|
Varistor
|
Output data
Nominal output voltage
|
24 V DC ±1 %
|
Setting range of the output voltage (USet)
|
22.5 V DC ... 28.5 V DC
|
Nominal output current (IN)
|
5 A (up to 60 °C)
|
POWER BOOST (IBoost)
|
7.5 A
|
Derating
|
60 °C ... 70 °C (2.5%/K)
|
Connection in parallel
|
yes, for redundancy and increased capacity
|
Connection in series
|
yes
|
Feedback voltage resistance
|
35 V DC
|
Protection against overvoltage at the output (OVP)
|
≤ 35 V DC
|
Max. capacitive load
|
unlimited
|
Active current limitation
|
Approx. IBOOST = 7.5 A (for short-circuit)
|
Control deviation
|
< 1 % (change in load, static 10 % ... 90 %)
|
|
< 2 % (change in load, dynamic 10 % ... 90 %)
|
|
< 0.1 % (change in input voltage ±10 %)
|
Residual ripple
|
< 10 mVPP (with nominal values)
|
Output power
|
120 W
|
Typical response time
|
< 1 s
|
Peak switching voltages nominal load
|
< 30 mVPP (20 MHz)
|
Maximum power dissipation in no-load condition
|
< 2 W
|
Power loss nominal load max.
|
< 14 W
|
General
Net weight
|
0.83 kg
|
Operating voltage display
|
Green LED
|
Efficiency
|
> 89 %
|
MTBF (IEC 61709, SN 29500)
|
> 500000 h
|
Insulation voltage input/output
|
4 kV AC (type test)
|
|
2 kV AC (routine test)
|
Insulation voltage input / PE
|
3.5 kV AC (type test)
|
|
2 kV AC (routine test)
|
Insulation voltage output / PE
|
500 V DC (routine test)
|
Degree of protection
|
IP20
|
Protection class
|
I (with PE connection)
|
Mounting position
|
horizontal DIN rail NS 35, EN 60715
|
Assembly instructions
|
alignable: horizontally 0 mm, vertically 50 mm
|
Connection data, input
Connection method
|
Pluggable screw connection
|
Conductor cross section solid min.
|
0.2 mm²
|
Conductor cross section solid max.
|
2.5 mm²
|
Conductor cross section flexible min.
|
0.2 mm²
|
Conductor cross section flexible max.
|
2.5 mm²
|
Conductor cross section AWG min.
|
24
|
Conductor cross section AWG max.
|
12
|
Stripping length
|
7 mm
|
Screw thread
|
M3
|
Connection data, output
Connection method
|
Pluggable screw connection
|
Conductor cross section solid min.
|
0.2 mm²
|
Conductor cross section solid max.
|
2.5 mm²
|
Conductor cross section flexible min.
|
0.2 mm²
|
Conductor cross section flexible max.
|
2.5 mm²
|
Conductor cross section AWG min.
|
24
|
Conductor cross section AWG max.
|
12
|
Stripping length
|
7 mm
|
Screw thread
|
M3
|
Signaling
Output name
|
DC OK active
|
Output description
|
UOUT > 0.9 x UN: High signal
|
Maximum switching voltage
|
≤ 24 V
|
Output voltage
|
+ 24 V DC (Signal)
|
Maximum inrush current
|
≤ 40 mA
|
Continuous load current
|
≤ 40 mA
|
Status display
|
"DC OK" LED green
|
Note on status display
|
UOUT < 0.9 x UN: LED flashing
|
Conductor cross section solid min.
|
0.2 mm²
|
Conductor cross section solid max.
|
2.5 mm²
|
Conductor cross section flexible min.
|
0.2 mm²
|
Conductor cross section flexible max.
|
2.5 mm²
|
Conductor cross section AWG min.
|
24
|
Conductor cross section AWG max.
|
12
|
Tightening torque, min
|
0.5 Nm
|
Tightening torque max
|
0.6 Nm
|
Screw thread
|
M3
|
Output name
|
DC OK floating
|
Output description
|
Relay contact, UOUT > 0.9 x UN: Contact closed
|
Maximum switching voltage
|
≤ 30 V AC/DC
|
Maximum inrush current
|
≤ 1 A
|
Continuous load current
|
≤ 1 A
|
Status display
|
"DC OK" LED green
|
Standards and Regulations
Electromagnetic compatibility
|
Conformance with EMC Directive 2014/30/EU
|
Noise emission
|
EN 55011 (EN 55022)
|
Noise immunity
|
EN 61000-6-2
|
Connection in acc. with standard
|
CUL
|
Standards/regulations
|
EN 61000-4-2
|
Contact discharge
|
8 kV
|
Standards/regulations
|
EN 61000-4-3
|
Frequency range
|
80 MHz ... 2 GHz
|
Test field strength
|
10 V/m
|
Standards/regulations
|
EN 61000-4-4
|
|
EN 61000-6-3
|
|
EN 61000-4-6
|
Frequency range
|
0.15 MHz ... 80 MHz
|
Voltage
|
10 V
|
Standards/regulations
|
EN 61000-4-11
|
Low Voltage Directive
|
Conformance with Low Voltage Directive 2014/35/EC
|
Standard - Electrical safety
|
EN 62368-1
|
Standard – Safety extra-low voltage
|
EN 62368-1 (SELV)
|
|
EN 60204 (PELV)
|
Standard - Safe isolation
|
DIN VDE 0100-410
|
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment
|
EN 62368-1
|
Standard – Limitation of mains harmonic currents
|
EN 61000-3-2
|
Standard - Equipment safety
|
GS (tested safety)
|
Shipbuilding approval
|
DNV GL (EMC A)
|
UL approvals
|
UL/C-UL Recognized UL 60950-1
|
|
UL/C-UL listed UL 508
|
|
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
|
Shock
|
18 ms, 30g, in each space direction (according to IEC 60068-2-27)
|
Vibration (operation)
|
< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
|
|
15 Hz ... 150 Hz, 2.3g, 90 min.
|
Certificate
|
CB Scheme
|
Overvoltage category (EN 62477-1)
|
III
|
Environmental Product Compliance
REACh SVHC
|
Lead 7439-92-1
|
China RoHS
|
Environmentally Friendly Use Period = 25;
|
|
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
|
ECLASS
ECLASS 10.0.1 |
27040701
|
ECLASS 11.0 |
27040701
|
ECLASS 4.0 |
27040700
|
ECLASS 4.1 |
27040700
|
ECLASS 5.0 |
27049000
|
ECLASS 5.1 |
27049000
|
ECLASS 6.0 |
27049000
|
ECLASS 7.0 |
27049002
|
ECLASS 9.0 |
27040701
|
ETIM
ETIM 2.0 |
EC001039
|
ETIM 3.0 |
EC001039
|
ETIM 4.0 |
EC000599
|
ETIM 6.0 |
EC002540
|
ETIM 7.0 |
EC002540
|
UNSPSC
UNSPSC 6.01 |
30211502
|
UNSPSC 7.0901 |
39121004
|
UNSPSC 11 |
39121004
|
UNSPSC 12.01 |
39121004
|
UNSPSC 13.2 |
39121004
|
UNSPSC 18.0 |
39121004
|
UNSPSC 19.0 |
39121004
|
UNSPSC 20.0 |
39121004
|
UNSPSC 21.0 |
39121004
|
|
File description
|
File type
|
Download link
|
|
|
|
|
|
|
|
|
|