|
|
|
Image is illustrative
|
Surge Protection Plug PT 4-EX(I)-24DC-ST, Phoenix Code:
2839253
Price
€1,161.00
/pk
(€1,416.42 /pk with VAT)
Package 10pc, unit price
116.1EUR/pc
Manufacturer
:
Availability:
28 days
|
Weight:
0.0275 kg/pc
|
Volume:
0 m3/pc
|
|
|
|
|
Surge Protection Plug PT 4-EX(I)-24DC-ST, PhoenixDimensions
Height
|
45 mm
|
Width
|
17.7 mm
|
Depth
|
52 mm
|
Horizontal pitch
|
1 Div.
|
Complete module height
|
90 mm
|
Complete module width
|
17.7 mm
|
Complete module depth
|
65.5 mm
|
Ambient conditions
Ambient temperature (operation)
|
-40 °C ... 85 °C
|
Ambient temperature (storage/transport)
|
-40 °C ... 85 °C
|
Altitude
|
≤ 2000 m (amsl (above mean sea level))
|
Degree of protection
|
IP20
|
General
Housing material
|
PA 6.6
|
Flammability rating according to UL 94
|
V-0
|
Color
|
sky blue RAL 5015
|
Mounting type
|
on base element
|
Type
|
Male
|
Number of positions
|
4
|
Direction of action
|
Line-Line & Line-Signal Ground/Shield & Signal Ground/Shield-Earth Ground
|
Arrester can be tested with CHECKMASTER from software version:
|
From SW rev. 1.00
|
Protective circuit
IEC test classification
|
C1
|
|
C2
|
|
C3
|
|
D1
|
Nominal voltage UN
|
24 V DC
|
Maximum continuous voltage UC
|
30 V DC
|
|
21 V AC
|
Rated current
|
500 mA (40 °C)
|
Operating effective current IC at UC
|
≤ 5 µA
|
Residual current IPE
|
≤ 4 µA
|
Nominal discharge current In (8/20) µs (line-line)
|
308 A
|
Nominal discharge current In (8/20) µs (line-earth)
|
10 kA
|
Pulse discharge current Iimp (10/350) µs (line-earth)
|
1 kA
|
|
2 kA (in total)
|
Total discharge current Itotal (8/20) µs
|
20 kA
|
Total discharge current Itotal (10/350) µs
|
2 kA
|
Max. discharge current Imax (8/20) µs maximum (line-line)
|
308 A
|
Max. discharge current Imax (8/20) µs maximum (line-earth)
|
20 kA (in total)
|
Nominal pulse current Ian (10/1000) µs (line-line)
|
59 A
|
Output voltage limitation at 1 kV/µs (line-line) spike
|
≤ 45 V
|
Output voltage limitation at 1 kV/µs (line-earth) spike
|
≤ 1 kV
|
Output voltage limitation at 1 kV/µs (line-line) static
|
≤ 45 V
|
Output voltage limitation at 1 kV/µs (line-earth) static
|
≤ 1 kV
|
Residual voltage at In (line-line)
|
≤ 70 V
|
Residual voltage with Ian (10/1000) µs (line-line)
|
≤ 65 V
|
Voltage protection level Up (line-line)
|
≤ 60 V (C1 - 500 V / 250 A)
|
|
≤ 50 V (C3 - 10 A)
|
|
≤ 50 V (C3 - 25 A)
|
Voltage protection level Up (line-earth)
|
≤ 1 kV (C1 - 1 kV/500 A)
|
|
≤ 1 kV (C2 - 2 kV/1 kA)
|
|
≤ 1 kV (C2 - 10 kV / 5 kA)
|
|
≤ 1 kV (D1 - 1 kA)
|
Response time tA (line-line)
|
≤ 1 ns
|
Response time tA (line-earth)
|
≤ 100 ns
|
Input attenuation aE, sym.
|
typ. 0.1 dB (≤ 1 MHz / 50 Ω)
|
|
typ. 0.1 dB (≤ 500 kHz / 150 Ω)
|
|
typ. 0.1 dB (≤ 100 kHz / 600 Ω)
|
Cut-off frequency fg (3 dB), sym. in 50 Ω system
|
typ. 7 MHz
|
Cut-off frequency fg (3 dB), sym. in 150 Ω system
|
typ. 2.5 MHz
|
Cut-off frequency fg (3 dB), sym. in 600 Ω system
|
typ. 600 kHz
|
Resistance per path
|
0 Ω
|
Surge protection fault message
|
none
|
Max. required back-up fuse
|
500 mA (T)
|
Impulse durability (line-line)
|
C1 - 0.5 kV / 250 A
|
|
C3 - 10 A
|
|
C3 - 25 A
|
Impulse durability (line-earth)
|
C1 - 1 kV / 500 A
|
|
C2 - 2 kV / 1 kA
|
|
C2 - 10 kV / 5 kA
|
|
D1 - 1 kA
|
Alternating current carrying capacity (line-earth)
|
5 A - 1 s
|
Connection data
Connection method
|
Screw connection (in connection with the base element)
|
Screw thread
|
M3
|
Tightening torque
|
0.5 Nm
|
Stripping length
|
8 mm
|
Conductor cross section flexible
|
0.2 mm² ... 2.5 mm²
|
Conductor cross section solid
|
0.2 mm² ... 4 mm²
|
Conductor cross section AWG
|
24 ... 12
|
Standards and Regulations
Standards/specifications
|
EN 61643-21 A2:2013
|
|
EN 60079-0 2012
|
|
EN 60079-11 2012
|
|
EN 60079-26 2007
|
|
IEC 61643-21 A2:2012
|
|
IEC 60079-0 2011
|
|
IEC 60079-11 2011
|
|
IEC 60079-26 2006
|
General
Maximum inner capacitance Ci
|
1.1 nF
|
Max. internal inductance Li
|
1 µH
|
Maximum inner time factor (Ri/Li)
|
≤ 10 µs
|
Max. input current Ii
|
500 mA (T4 / ≤ 80°C)
|
|
500 mA (T5 / ≤ 55 °C)
|
|
500 mA (T6 / ≤ 40 °C)
|
Max. input voltage Ui
|
30 V DC
|
max. input power Pi
|
850 mW (T4 / ≤ 80°C)
|
|
700 mW (T5 / ≤ 55 °C)
|
|
700 mW (T6 / ≤ 40 °C)
|
Ambient temperature (operation)
|
-40 °C ... 80 °C (T4)
|
|
-40 °C ... 55 °C (T5)
|
|
-40 °C ... 40 °C (T6)
|
Conformity / approvals
ATEX
|
II 1G Ex ia IIC T4...T6 Ga
|
|
II 1D Ex ia IIIC T135°C...T85°C Da
|
IECEx
|
Ex ia IIC T4...T6 Ga
|
|
Ex ia IIIC T135 °C...T85 °C Da
|
Environmental Product Compliance
REACh SVHC
|
Lead 7439-92-1
|
China RoHS
|
Environmentally friendly use period: unlimited = EFUP-e
|
|
No hazardous substances above threshold values
|
ECLASS
ECLASS 10.0.1 |
27130807
|
ECLASS 11.0 |
27130807
|
ECLASS 4.0 |
27130800
|
ECLASS 4.1 |
27130800
|
ECLASS 5.0 |
27130800
|
ECLASS 5.1 |
27130800
|
ECLASS 6.0 |
27130800
|
ECLASS 7.0 |
27130807
|
ECLASS 9.0 |
27130807
|
ETIM
ETIM 2.0 |
EC000943
|
ETIM 3.0 |
EC000943
|
ETIM 4.0 |
EC000943
|
ETIM 6.0 |
EC000943
|
ETIM 7.0 |
EC000943
|
UNSPSC
UNSPSC 6.01 |
30212010
|
UNSPSC 7.0901 |
39121610
|
UNSPSC 11 |
39121610
|
UNSPSC 12.01 |
39121610
|
UNSPSC 13.2 |
39121620
|
UNSPSC 18.0 |
39121620
|
UNSPSC 19.0 |
39121620
|
UNSPSC 20.0 |
39121620
|
UNSPSC 21.0 |
39121620
|
|
File description
|
File type
|
Download link
|
|
|
|
|
|
|
|
|