Image is illustrative
|
Surge Protection Plug PT 3-HF-12DC-ST, Phoenix Code:
2858043
Price
€569.00
/pk
(€694.18 /pk with VAT)
Package 10pc, unit price
56.9EUR/pc
Manufacturer
:
Availability:
28 days
|
Weight:
0.0215 kg/pc
|
Volume:
0 m3/pc
|
|
|
|
|
Surge Protection Plug PT 3-HF-12DC-ST, PhoenixDimensions
Height
|
45 mm
|
Width
|
17.7 mm
|
Depth
|
52 mm
|
Horizontal pitch
|
1 Div.
|
Complete module height
|
90 mm
|
Complete module width
|
17.7 mm
|
Complete module depth
|
65.5 mm
|
Ambient conditions
Ambient temperature (operation)
|
-40 °C ... 85 °C
|
Altitude
|
max. 2000 m
|
Degree of protection
|
IP20
|
General
Housing material
|
PA
|
Flammability rating according to UL 94
|
V-0
|
Color
|
black
|
Standards for cearances and creepage distances
|
DIN EN 61664-1
|
|
IEC 60664-1
|
Mounting type
|
on base element
|
Type
|
Male
|
Number of positions
|
3
|
Direction of action
|
Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
|
Arrester can be tested with CHECKMASTER from software version:
|
From SW rev. 1.10
|
Protective circuit
IEC test classification
|
C1
|
|
C2
|
|
C3
|
|
D1
|
VDE requirement class
|
C1
|
|
C2
|
|
C3
|
|
D1
|
Nominal voltage UN
|
12 V DC
|
Maximum continuous voltage UC
|
14 V DC
|
|
9.8 V AC
|
Rated current
|
450 mA (45 °C)
|
Operating effective current IC at UC
|
≤ 5 µA
|
Residual current IPE
|
< 5 µA (with PT 1X2-BE)
|
|
< 1 µA (with PT 1X2+F-BE)
|
Nominal discharge current In (8/20) µs (line-line)
|
10 kA
|
Nominal discharge current In (8/20) µs (line-earth)
|
10 kA
|
Nominal discharge current In (8/20) µs (line-signal ground)
|
10 kA
|
Pulse discharge current Iimp (10/350) µs
|
2.5 kA
|
Total discharge current Itotal (8/20) µs
|
20 kA
|
Max. discharge current Imax (8/20) µs maximum (line-line)
|
10 kA
|
Max. discharge current Imax (8/20) µs maximum (line-earth)
|
10 kA
|
Nominal pulse current Ian (10/1000) µs (line-line)
|
67 A
|
Output voltage limitation at 1 kV/µs (line-line) spike
|
≤ 55 V
|
Output voltage limitation at 1 kV/µs (line-earth) spike
|
≤ 55 V (with PT 1X2-BE)
|
|
≤ 700 V (with PT 1X2+F-BE)
|
Output voltage limitation at 1 kV/µs (line-line) static
|
≤ 25 V
|
Output voltage limitation at 1 kV/µs (line-earth) static
|
≤ 25 V
|
|
≤ 40 V (with PT 1X2+F-BE)
|
Residual voltage at In (line-line)
|
≤ 25 V
|
Residual voltage at In (line-earth)
|
≤ 40 V (with PT 1X2-BE)
|
Residual voltage at In (line-signalground)
|
≤ 25 V (with PT 1X2-BE)
|
Residual voltage with Ian (10/1000) µs (line-line)
|
≤ 25 V
|
Residual voltage with Ian (10/1000) µs (line-signalground)
|
≤ 25 V
|
Voltage protection level Up (line-line)
|
≤ 50 V (C3 - 25 A)
|
|
≤ 80 V (C1 - 1 kV/500 A)
|
|
≤ 110 V (C2 - 10 kV / 5 kA)
|
|
≤ 80 V (6 kV / 3 kA)
|
Voltage protection level Up (line-earth)
|
≤ 50 V (C3 - 25 A)
|
|
≤ 85 V (C1 - 1 kV/500 A)
|
|
≤ 140 V (C2 - 10 kV / 5 kA)
|
|
≤ 100 V (6 kV / 3 kA)
|
Voltage protection level Up (line-signalground)
|
≤ 50 V (C3 - 25 A)
|
Response time tA (line-line)
|
≤ 500 ns
|
Response time tA (line-earth)
|
≤ 500 ns
|
Input attenuation aE, sym.
|
typ. 0.3 dB (≤ 5 MHz / 100 Ω)
|
Cut-off frequency fg (3 dB), sym. in 100 Ω system
|
typ. 60 MHz
|
Capacity (line-line)
|
typ. 30 pF
|
Resistance per path
|
2.2 Ω ±10 % (7-8/11-12)
|
Max. required back-up fuse
|
500 mA (T)
|
Impulse durability (line-line)
|
C2 - 10 kV / 5 kA
|
|
C3 - 67 A
|
Impulse durability (line-earth)
|
C2 - 10 kV / 5 kA
|
|
C3 - 67 A
|
|
D1 - 2.5 kA
|
Connection data
Connection method
|
Screw connection (in connection with the base element)
|
Screw thread
|
M3
|
Tightening torque
|
0.8 Nm
|
Stripping length
|
8 mm
|
Conductor cross section flexible
|
0.2 mm² ... 2.5 mm²
|
Conductor cross section solid
|
0.2 mm² ... 4 mm²
|
Conductor cross section AWG
|
24 ... 12
|
Connection, equipotential bonding
Stripping length
|
8 mm
|
Conductor cross section flexible min.
|
0.2 mm²
|
Conductor cross section flexible max.
|
2.5 mm²
|
Conductor cross section solid min.
|
0.2 mm²
|
Conductor cross section solid max.
|
4 mm²
|
Conductor cross section AWG min.
|
24
|
Conductor cross section AWG max.
|
12
|
Standards and Regulations
Standards/specifications
|
EN 61643-21/A1 2009
|
|
IEC 61643-21/A1 2008
|
Environmental Product Compliance
REACh SVHC
|
Lead 7439-92-1
|
China RoHS
|
Environmentally Friendly Use Period = 50 years
|
|
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
|
ECLASS
ECLASS 10.0.1 |
27130807
|
ECLASS 11.0 |
27130807
|
ECLASS 4.0 |
27130800
|
ECLASS 4.1 |
27130800
|
ECLASS 5.0 |
27130800
|
ECLASS 5.1 |
27130800
|
ECLASS 6.0 |
27130800
|
ECLASS 7.0 |
27130807
|
ECLASS 9.0 |
27130807
|
ETIM
ETIM 2.0 |
EC000943
|
ETIM 3.0 |
EC000943
|
ETIM 4.0 |
EC000943
|
ETIM 6.0 |
EC000943
|
ETIM 7.0 |
EC000943
|
UNSPSC
UNSPSC 6.01 |
30212010
|
UNSPSC 7.0901 |
39121610
|
UNSPSC 11 |
39121610
|
UNSPSC 12.01 |
39121610
|
UNSPSC 13.2 |
39121620
|
UNSPSC 18.0 |
39121620
|
UNSPSC 19.0 |
39121620
|
UNSPSC 20.0 |
39121620
|
UNSPSC 21.0 |
39121620
|
|
File description
|
File type
|
Download link
|
|
|
|
|
|
|
|
|