Supply voltage |
Load voltage L+ |
● Rated value (DC) |
24 V |
Input current |
from backplane bus 5 V DC, max. |
120 mA |
Power loss |
Power loss, typ. |
0.6 W |
Analog inputs |
Number of analog inputs |
8; 8x thermocouples; 4x RTD thermoresistors |
Input ranges |
● Voltage |
Yes |
● Current |
No |
● Thermocouple |
Yes |
● Resistance thermometer |
Yes |
● Resistance |
Yes |
Input ranges (rated values), thermocouples |
● Type B |
Yes |
● Input resistance (Type B) |
10 MΩ |
● Type E |
Yes |
● Input resistance (Type E) |
10 MΩ |
● Type J |
Yes |
● Input resistance (type J) |
10 MΩ |
● Type K |
Yes |
● Input resistance (Type K) |
10 MΩ |
● Type L |
Yes |
● Input resistance (Type L) |
10 MΩ |
● Type N |
Yes |
● Input resistance (Type N) |
10 MΩ |
● Type R |
Yes |
● Input resistance (Type R) |
10 MΩ |
● Type S |
Yes |
● Input resistance (Type S) |
10 MΩ |
● Type T |
Yes |
● Input resistance (Type T) |
10 MΩ |
● Type U |
Yes |
● Input resistance (Type U) |
10 MΩ |
Input ranges (rated values), resistance thermometer |
● Ni 100 |
Yes |
● Input resistance (Ni 100) |
10 MΩ |
● Pt 100 |
Yes |
● Input resistance (Pt 100) |
10 MΩ |
● Pt 200 |
Yes |
● Input resistance (Pt 200) |
10 MΩ |
Cable length |
● shielded, max. |
200 m; TC: 50 m |
Analog value generation for the inputs |
Measurement principle |
Sigma Delta |
Integration and conversion time/resolution per channel |
● Resolution with overrange (bit including sign), max. |
16 bit; 10 bit to 15 bit + sign |
● Integration time, parameterizable |
Yes; 2.5 to 100 ms |
● Interference voltage suppression for interference frequency f1 in Hz |
10 to 400 Hz |
Encoder |
Connection of signal encoders |
● for current measurement as 2-wire transducer |
Yes |
● for current measurement as 4-wire transducer |
Yes |
Errors/accuracies |
Temperature error (relative to input range), (+/-) |
Temperature error: 0.001 to 0.002 %/K |
Operational error limit in overall temperature range |
● Resistance thermometer, relative to input range, (+/-) |
0.09 to 0.04% |
Basic error limit (operational limit at 25 °C) |
● Resistance thermometer, relative to input range, (+/-) |
0.1 % |
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency |
● Series mode interference (peak value of interference < rated value of input range), min. |
60 dB |
● Common mode interference, min. |
130 dB |
Interrupts/diagnostics/status information |
Diagnostic functions |
Yes |
Diagnostic messages |
● Diagnostic information readable |
Yes |
● Overrange |
Yes |
● Wire-break in signal transmitter cable |
Yes |
● Short-circuit of the signal encoder cable |
Yes |
Diagnostics indication LED |
● Group error SF (red) |
Yes |
● Channel fault indicator F (red) |
Yes |
Ex(i) characteristics |
Module for Ex(i) protection |
Yes |
Maximum values of input circuits (per channel) |
● Co (permissible external capacity), max. |
43 µF |
● Io (short-circuit current), max. |
28.8 mA |
● Lo (permissible external inductivity), max. |
40 mH |
● Po (power of load), max. |
41.4 mW |
● Uo (output no-load voltage), max. |
5.9 V |
Potential separation |
Potential separation analog inputs |
● Potential separation analog inputs |
Yes |
Permissible potential difference |
between the inputs (UCM) |
60 V DC/30 V AC when used in the hazardous area; 400 V DC/250 V AC when used in NON-hazardous area |
Between the inputs and MANA (UCM) |
60 V DC/30 V AC when used in the hazardous area; 400 V DC/250 V AC when used in NON-hazardous area |
Standards, approvals, certificates |
CE mark |
Yes |
UL approval |
Yes; File E239877 |
FM approval |
Yes; CofC 3028431 |
RCM (formerly C-TICK) |
Yes |
KC approval |
Yes |
EAC (formerly Gost-R) |
Yes |
Railway application |
● EN 50155 |
No |
Use in hazardous areas |
● Test number KEMA |
KEMA 09 ATEX 0077X |
Ambient conditions |
Ambient temperature during operation |
● min. |
0 °C; = Tmin |
● max. |
60 °C; = Tmax |
Ambient temperature during storage/transportation |
● min. |
-40 °C |
● max. |
70 °C |
Altitude during operation relating to sea level |
● Ambient air temperature-barometric pressure-altitude |
Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) |
Relative humidity |
● With condensation, tested in accordance with IEC 60068-2-38, max. |
100 %; RH incl. condensation/frost (no commissioning under condensation conditions) |
Resistance |
Use in stationary industrial systems |
— to biologically active substances according to EN 60721-3-3 |
Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request |
— to chemically active substances according to EN 60721-3-3 |
Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! |
— to mechanically active substances according to EN 60721-3-3 |
Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! |
Connection method |
required front connector |
20-pin |
Weights |
Weight, approx. |
210 g |
last modified: |
11/20/2017 |