General information |
Product type designation |
IM 155-5 PN ST |
HW functional status |
FS01 |
Firmware version |
V4.1.0 |
Vendor identification (VendorID) |
0x002A |
Device identifier (DeviceID) |
0X0312 |
Product function |
● I&M data |
Yes; I&M0 to I&M3 |
Engineering with |
● STEP 7 TIA Portal configurable/integrated as of version |
V14 or higher with HSP 0223 / integrated with V15 or higher |
● STEP 7 configurable/integrated as of version |
GSDML V2.32 |
● PROFINET as of GSD version/GSD revision |
V2.3 / - |
Configuration control |
via user data |
No |
via dataset |
Yes |
Supply voltage |
Rated value (DC) |
24 V |
permissible range, lower limit (DC) |
20.4 V |
permissible range, upper limit (DC) |
28.8 V |
Reverse polarity protection |
Yes |
Short-circuit protection |
Yes |
Mains buffering |
● Mains/voltage failure stored energy time |
10 ms |
Input current |
Current consumption (rated value) |
0.2 A |
Current consumption, max. |
1.2 A |
Inrush current, max. |
9 A |
I²t |
0.09 A²·s |
Power |
Infeed power to the backplane bus |
14 W |
Power available from the backplane bus |
2.3 W |
Power loss |
Power loss, typ. |
4.5 W |
Address area |
Address space per module |
● Address space per module, max. |
256 byte; per input / output |
Address space per station |
● Address space per station, max. |
512 byte; per input / output |
Hardware configuration |
Integrated power supply |
Yes |
System power supply can be plugged in to left of IM |
Yes |
Number of permissible power segments |
3 |
Rack |
● Modules per rack, max. |
30; I/O modules |
Interfaces |
Number of PROFINET interfaces |
1 |
1. Interface |
Interface types |
● Number of ports |
2 |
● integrated switch |
Yes |
● RJ 45 (Ethernet) |
Yes |
Protocols |
● PROFINET IO Device |
Yes |
● Media redundancy |
Yes; PROFINET MRP |
Interface types |
RJ 45 (Ethernet) |
● Transmission procedure |
PROFINET with 100 Mbit/s full duplex (100BASE-TX) |
● 100 Mbps |
Yes |
● Autonegotiation |
Yes |
● Autocrossing |
Yes |
Protocols |
PROFINET IO Device |
Services |
— Isochronous mode |
Yes |
— Open IE communication |
Yes |
— IRT |
Yes |
— PROFIenergy |
No |
— Prioritized startup |
Yes |
— Shared device |
Yes |
— Number of IO Controllers with shared device, max. |
2 |
Redundancy mode |
● MRP |
Yes |
● MRPD |
No |
● PROFINET system redundancy (S2) |
No |
● Redundant PROFINET configuration (R1) |
No |
Open IE communication |
● TCP/IP |
Yes |
● SNMP |
Yes |
● LLDP |
Yes |
Isochronous mode |
Isochronous operation (application synchronized up to terminal) |
Yes |
Equidistance |
Yes |
shortest clock pulse |
250 µs |
max. cycle |
4 ms |
Interrupts/diagnostics/status information |
Status indicator |
Yes |
Alarms |
Yes |
Diagnostics function |
Yes |
Diagnostics indication LED |
● RUN LED |
Yes; Green LED |
● ERROR LED |
Yes; Red LED |
● MAINT LED |
Yes; Yellow LED |
● Connection display LINK TX/RX |
Yes; 2x green-yellow LEDs |
Potential separation |
between backplane bus and electronics |
No |
between PROFINET and all other circuits |
Yes |
between supply and all other circuits |
No |
Isolation |
Isolation tested with |
707 V DC (type test) |
Ambient conditions |
Ambient temperature during operation |
● horizontal installation, min. |
0 °C |
● horizontal installation, max. |
60 °C |
● vertical installation, min. |
0 °C |
● vertical installation, max. |
40 °C |
Altitude during operation relating to sea level |
● Installation altitude above sea level, max. |
2 000 m |
Connection method |
ET-Connection |
● via BU/BA Send |
No |
Dimensions |
Width |
35 mm |
Height |
147 mm |
Depth |
129 mm |
last modified: |
05/30/2019 |