Image is illustrative
|
Master Interface Module inRAx ProfiBus DP-V1, debug/configuration port, RJ45 » DB-9M, 6ft RS232, LED, 800mA 5.1VDC backplane, TS35, ProSoft Code:
MVI56-PDPMV1
Price (indicative)
€4,424.20
/pc
(€5,397.52 /pc with VAT)
Manufacturer
:
Availability:
21 days
|
Weight:
0.759 kg/pc
|
Volume:
0.0046 m3/pc
|
|
|
|
|
Master Interface Module inRAx® ProfiBus DP-V1, debug/configuration port, RJ45 to DB-9M, 6ft RS232, LED, 800mA 5.1VDC backplane, TS35, Prosoft
DESCRIPTIONS
-
inRAx® PROFIBUS DP-V1 Master Interface Module, Communication Protocol: PROFIBUS DP-V1, Interface: Debug/Configuration Port, Power Supply: Backplane Current Load: 800 MA At 5.1 VDC, Connection Cables: RJ45 To DB-9 M, 6 FT RS-232, Mounting: DIN Rail, Temperature Rating: 0 - 60 DEG C Operating, Indicator: LED: Module Status, Backplane Transfer Status, Application Status, Serial Activity And Error LED Status, Environmental Conditions: Storage Temperature: -40 To 85 DEG C, Shock: 30 G Operational, 50G Non-Operational, Vibration: 5 G From 10 To 150 HZ, Relative Humidity: 5 To 95% (Non-Condensing), Application: For ControlLogix processors
SPECIFICATIONS
-
-
Item Name: PROFIBUS DP-V1 Master Interface Module
-
Sub Brand: inRAx®
-
Communication Protocol: PROFIBUS DP-V1
-
Interface: Debug/Configuration Port
-
Power Supply: Backplane Current Load: 800 MA At 5.1 VDC
-
Connection Cables: RJ45 To DB-9 M, 6 FT RS-232
-
Mounting: DIN Rail
-
Temperature Rating: 0 - 60 DEG C Operating
-
Environmental Conditions: Storage Temperature: -40 To 85 DEG C, Shock: 30 G Operational, 50G Non-Operational, Vibration: 5 G From 10 To 150 HZ, Relative Humidity: 5 To 95% (Non-Condensing)
-
Indicator: LED: Module Status, Backplane Transfer Status, Application Status, Serial Activity And Error LED Status
FEATURES
-
- Module allows ControlLogix processors to easily communicate with slave devices supporting PROFIBUS DP-V0 and DP-V1 protocol
- The module acts as an input/output module between the PROFIBUS network and the processor supporting complete Master specifications according to IEC 61158
- The module supports complete Master specifications according to IEC 61158
- Acyclic parameter data can be transferred with Class 1 or Class 2 DPV1 services, allowing processors to easily communicate with slave devices supporting PROFIBUS DPV0/V1 protocol
- The module acts as an input/output module between the PROFIBUS network and the ControlLogix processor
- Data transfer from the processor is asynchronous with the I/O data transfer on the PROFIBUS network
- Databases are user-defined and stored in the module to hold the data required by the protocol
- Applications: For ControlLogix processors
|
|
|
|
|