Image is illustrative
|
Marshalling Panel PTRV 4 /SENSOR 4POL, 10pcs/pck, Phoenix Code:
1162613
Price
€125.00
/pk
(€152.50 /pk with VAT)
Package 10pc, unit price
12.5EUR/pc
Manufacturer
:
Availability:
21 days
|
Weight:
0.0186 kg/pc
|
|
|
|
|
|
Marshalling Panel PTRV 4 /SENSOR 4POL, 10pcs/pck, PhoenixGeneral
Number of positions
|
2
|
Number of rows
|
4
|
Number of connections
|
16
|
Potentials
|
4
|
Nominal cross section
|
1.5 mm²
|
Color
|
gray
|
Color of connection elements
|
white
|
Insulating material
|
PA
|
Flammability rating according to UL 94
|
V0
|
Mounting type
|
NS 35/7,5
|
Rated surge voltage
|
6 kV
|
Overvoltage category
|
III
|
Insulating material group
|
I
|
Maximum load current
|
10 A (with 1.5 mm² conductor cross section)
|
Nominal current IN
|
10 A
|
Nominal voltage UN
|
250 V
|
Open side panel
|
Yes
|
Dimensions
Width
|
8.3 mm
|
Length
|
64 mm
|
Height NS 35/7,5
|
55.5 mm
|
Height NS 35/15
|
63 mm
|
Connection data
Connection
|
1st, 2nd, 3rd and 4th level
|
Connection method
|
Push-in connection
|
Stripping length
|
8 mm ... 10 mm
|
Connection in acc. with standard
|
IEC 60947-7-1
|
Conductor cross section solid min.
|
0.14 mm²
|
Conductor cross section solid max.
|
2.5 mm²
|
Conductor cross section AWG min.
|
26
|
Conductor cross section AWG max.
|
14
|
Conductor cross section flexible min.
|
0.14 mm²
|
Conductor cross section flexible max.
|
1.5 mm²
|
Min. AWG conductor cross section, flexible
|
26
|
Max. AWG conductor cross section, flexible
|
14
|
Conductor cross section flexible, with ferrule without plastic sleeve min.
|
0.14 mm²
|
Conductor cross section flexible, with ferrule without plastic sleeve max.
|
1.5 mm²
|
Conductor cross section flexible, with ferrule with plastic sleeve min.
|
0.14 mm²
|
Conductor cross section flexible, with ferrule with plastic sleeve max.
|
1.5 mm²
|
Connection cross sections directly pluggable
|
0.34 mm² 2.5 mm² 20 14
|
Conductor cross section solid min.
|
0.34 mm²
|
Conductor cross section solid max.
|
2.5 mm²
|
Conductor cross section AWG min.
|
20
|
Conductor cross section AWG max.
|
14
|
Conductor cross section flexible, with ferrule without plastic sleeve min.
|
0.34 mm²
|
Conductor cross section flexible, with ferrule without plastic sleeve max.
|
1.5 mm²
|
Conductor cross section flexible, with ferrule with plastic sleeve min.
|
0.34 mm²
|
Conductor cross section flexible, with ferrule with plastic sleeve max.
|
1.5 mm²
|
Ambient conditions
Operating temperature
|
-60 °C ... 105 °C (max. short-term operating temperature 130°C)
|
Ambient temperature (storage/transport)
|
-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
|
Permissible humidity (storage/transport)
|
30 % ... 70 %
|
Ambient temperature (assembly)
|
-5 °C ... 70 °C
|
Ambient temperature (actuation)
|
-5 °C ... 70 °C
|
Standards and Regulations
Connection in acc. with standard
|
IEC 60947-7-1
|
Flammability rating according to UL 94
|
V0
|
ECLASS
ECLASS 10.0.1 |
27141120
|
ECLASS 11.0 |
27141120
|
ECLASS 4.0 |
27141100
|
ECLASS 4.1 |
27141100
|
ECLASS 5.0 |
27141100
|
ECLASS 5.1 |
27141100
|
ECLASS 6.0 |
27141100
|
ECLASS 7.0 |
27141120
|
ECLASS 9.0 |
27141120
|
ETIM
ETIM 2.0 |
EC000897
|
ETIM 3.0 |
EC000897
|
ETIM 4.0 |
EC000897
|
ETIM 6.0 |
EC000897
|
ETIM 7.0 |
EC000897
|
UNSPSC
UNSPSC 6.01 |
30211811
|
UNSPSC 7.0901 |
39121410
|
UNSPSC 11 |
39121410
|
UNSPSC 12.01 |
39121410
|
UNSPSC 13.2 |
39121410
|
UNSPSC 18.0 |
39121410
|
UNSPSC 19.0 |
39121410
|
UNSPSC 20.0 |
39121410
|
UNSPSC 21.0 |
39121410
|
|
File description
|
File type
|
Download link
|
|
|
|
|
|
|
|
|