Power Supply Unit QUINT4-PS/3AC/24DC/10, Phoenix Code:
2904621
Price (indicative)
€364.70
/pc
(€452.23 /pc with VAT)
Manufacturer
:
Availability:
21 days
|
Weight:
1.13 kg/pc
|
Volume:
0.0027 m3/pc
|
|
|
|
|
Power Supply Unit QUINT4-PS/3AC/24DC/10, PhoenixDimensions
Width
|
50 mm
|
Height
|
130 mm
|
Depth
|
125 mm
|
Width with alternative assembly
|
122 mm
|
Height with alternative assembly
|
130 mm
|
Depth with alternative assembly
|
53 mm
|
Installation distance right/left
|
5 mm / 5 mm
|
Installation distance top/bottom
|
50 mm / 50 mm
|
Ambient conditions
Degree of protection
|
IP20
|
Inflammability class in acc. with UL 94 (housing / terminal blocks)
|
V0
|
Ambient temperature (operation)
|
-25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
|
Ambient temperature (start-up type tested)
|
-40 °C
|
Ambient temperature (storage/transport)
|
-40 °C ... 85 °C
|
Max. permissible relative humidity (operation)
|
≤ 95 % (at 25 °C, non-condensing)
|
Climatic class
|
3K3 (in acc. with EN 60721)
|
Degree of pollution
|
2
|
Installation height
|
≤ 5000 m (> 2000 m, observe derating)
|
Input data
Nominal input voltage range
|
3x 400 V AC ... 500 V AC
|
|
2x 400 V AC ... 500 V AC
|
|
± 260 V DC ... 300 V DC
|
Input voltage range
|
3x 400 V AC ... 500 V AC -20 % ... +10 %
|
|
2x 400 V AC ... 500 V AC -10 % ... +10 %
|
|
± 260 V DC ... 300 V DC -13 % ... +30 %
|
AC frequency range
|
50 Hz ... 60 Hz -10 % ... +10 %
|
Frequency range (fN)
|
50 Hz ... 60 Hz -10 % ... +10 %
|
Discharge current to PE
|
< 3.5 mA
|
Current consumption
|
3x 0.5 A (400 V AC)
|
|
3x 0.41 A (480 V AC)
|
|
2x 1.1 A (400 V AC)
|
|
2x 0.91 A (480 V AC)
|
|
3x 0.4 A (500 V AC)
|
|
2x 1.1 A (500 V AC)
|
Nominal power consumption
|
274 VA
|
Inrush current
|
typ. 3 A (at 25 °C)
|
Mains buffering time
|
typ. 29 ms (3x 400 V AC)
|
|
typ. 26 ms (3x 480 V AC)
|
Recommended breaker for input protection
|
3x 4 A ... 20 A (Characteristic B, C or comparable)
|
Power factor (cos phi)
|
0.91
|
Type of protection
|
Transient surge protection
|
Protective circuit/component
|
Varistor, gas-filled surge arrester
|
Output data
Nominal output voltage
|
24 V DC
|
Setting range of the output voltage (USet)
|
24 V DC ... 29.5 V DC (constant capacity)
|
Nominal output current (IN)
|
10 A
|
Static Boost (IStat.Boost)
|
12.5 A
|
Dynamic Boost (IDyn.Boost)
|
20 A (5 s)
|
Selective Fuse Breaking (ISFB)
|
60 A (15 ms)
|
Derating
|
> 60 °C ... 70 °C (2.5%/K)
|
Connection in parallel
|
yes, for redundancy and increased capacity
|
Connection in series
|
yes
|
Feedback voltage resistance
|
≤ 35 V DC
|
Protection against overvoltage at the output (OVP)
|
≤ 32 V DC
|
Control deviation
|
< 0.5 % (Static load change 10 % ... 90 %)
|
|
< 2 % (Dynamic load change 10 % ... 90 %, (10 Hz))
|
|
< 0.25 % (change in input voltage ±10 %)
|
Residual ripple
|
< 75 mVPP (with nominal values)
|
Output power
|
240 W
|
Typical response time
|
300 ms (from SLEEP MODE)
|
Maximum power dissipation in no-load condition
|
< 5 W (400 V AC)
|
|
< 5 W (480 V AC)
|
Power loss nominal load max.
|
< 19 W (400 V AC)
|
|
< 20 W (480 V AC)
|
General
Net weight
|
0.9 kg
|
Environmental protection directive
|
RoHS Directive 2011/65/EU
|
|
WEEE
|
|
Reach
|
Efficiency
|
typ. 93 % (400 V AC)
|
|
typ. 92.6 % (480 V AC)
|
MTBF (IEC 61709, SN 29500)
|
> 1034000 h (25 °C)
|
|
> 654000 h (40 °C)
|
|
> 320000 h (60 °C)
|
Insulation voltage input/output
|
4 kV AC (type test)
|
|
2.4 kV AC (routine test)
|
Insulation voltage input / PE
|
3.5 kV AC (type test)
|
|
2.4 kV AC (routine test)
|
Insulation voltage output / PE
|
0.5 kV DC (type test)
|
|
0.5 kV DC (routine test)
|
Degree of protection
|
IP20
|
Protection class
|
I
|
Inflammability class in acc. with UL 94 (housing / terminal blocks)
|
V0
|
Mounting position
|
horizontal DIN rail NS 35, EN 60715
|
Assembly instructions
|
alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm vertically alignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
|
Connection data, input
Connection method
|
Screw connection
|
Conductor cross section solid min.
|
0.2 mm²
|
Conductor cross section solid max.
|
6 mm²
|
Conductor cross section flexible min.
|
0.2 mm²
|
Conductor cross section flexible max.
|
4 mm²
|
Conductor cross section AWG min.
|
24
|
Conductor cross section AWG max.
|
10
|
Stripping length
|
8 mm
|
Connection data, output
Connection method
|
Screw connection
|
Conductor cross section solid min.
|
0.2 mm²
|
Conductor cross section solid max.
|
2.5 mm²
|
Conductor cross section flexible min.
|
0.2 mm²
|
Conductor cross section flexible max.
|
2.5 mm²
|
Conductor cross section AWG min.
|
24
|
Conductor cross section AWG max.
|
14
|
Stripping length
|
6.5 mm
|
Connection data for signaling
Connection method
|
Push-in connection
|
Conductor cross section solid min.
|
0.2 mm²
|
Conductor cross section solid max.
|
1 mm²
|
Conductor cross section flexible min.
|
0.2 mm²
|
Conductor cross section flexible max.
|
1.5 mm²
|
Conductor cross section AWG min.
|
24
|
Conductor cross section AWG max.
|
16
|
Stripping length
|
8 mm
|
Standards
EMC requirements for noise immunity
|
EN 61000-6-1
|
|
EN 61000-6-2
|
EMC requirements for noise emission
|
EN 61000-6-3
|
|
EN 61000-6-4
|
EMC requirements, power plant
|
IEC 61850-3
|
|
EN 61000-6-5
|
HART FSK Physical Layer Test Specification Compliance
|
Output voltage UOut compliant
|
Standard - Safety of transformers
|
IEC 61558-2-16 pending
|
Standard - Electrical safety
|
IEC 61010-2-201 (SELV)
|
Standard - safety for equipment for measurement, control, and laboratory use
|
IEC 61010-1
|
Standard – Safety extra-low voltage
|
IEC 61010-1 (SELV)
|
|
IEC 61010-2-201 (PELV)
|
Standard - Safe isolation
|
IEC 61558-2-16 pending
|
Standard - power supply devices for low voltage with DC output
|
EN 61204-3
|
Standard – Limitation of mains harmonic currents
|
EN 61000-3-2
|
Mains variation/undervoltage
|
SEMI F47-0706, EN 61000-4-11
|
Rail applications
|
EN 50121-3-2
|
|
EN 50121-4
|
|
EN 50121-5
|
|
IEC 62236-3-2
|
|
IEC 62236-4
|
|
IEC 62236-5
|
Overvoltage category EN 61010-1
|
II (≤ 2000 m)
|
Overvoltage category EN 62477-1
|
III (≤ 2000 m)
|
Conformance/approvals
UL approvals
|
UL Listed UL 508
|
|
UL/C-UL Recognized UL 60950-1
|
|
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
|
CSA
|
CAN/CSA-C22.2 No. 60950-1-07
|
|
CSA-C22.2 No. 107.1-01
|
SIQ
|
BG (type approved)
|
Shipbuilding approval
|
DNV GL, PRS, BV, LR, ABS
|
EMC data
Electromagnetic compatibility
|
Conformance with EMC Directive 2014/30/EU
|
Low Voltage Directive
|
Conformance with Low Voltage Directive 2014/35/EC
|
Conducted noise emission
|
EN 55016
|
|
EN 61000-6-3 (Class B)
|
Noise emission
|
EN 55016
|
|
EN 61000-6-3 (Class B)
|
Harmonic currents
|
EN 61000-3-2
|
|
EN 61000-3-2 (Class A)
|
Flicker
|
EN 61000-3-3
|
|
EN 61000-3-3
|
DNV GL conducted interference
|
Class A
|
Additional text
|
Area power distribution
|
DNV GL noise radiation
|
Class B
|
Additional text
|
Bridge and deck area
|
Electrostatic discharge
|
EN 61000-4-2
|
Contact discharge
|
8 kV (Test Level 4)
|
Discharge in air
|
15 kV (Test Level 4)
|
Electromagnetic HF field
|
EN 61000-4-3
|
Frequency range
|
80 MHz ... 1 GHz
|
Test field strength
|
20 V/m (Test Level 3)
|
Frequency range
|
1 GHz ... 6 GHz
|
Test field strength
|
10 V/m (Test Level 3)
|
Frequency range
|
1 GHz ... 6 GHz
|
Test field strength
|
10 V/m (Test Level 3)
|
Comments
|
Criterion A
|
Fast transients (burst)
|
EN 61000-4-4
|
Input
|
4 kV (Test Level 4 - asymmetrical)
|
Output
|
4 kV (Test Level 4 - asymmetrical)
|
Signal
|
4 kV (Test Level 4 - asymmetrical)
|
Comments
|
Criterion A
|
Surge voltage load (surge)
|
EN 61000-4-5
|
Input
|
3 kV (Test Level 4 - symmetrical)
|
|
6 kV (Test Level 4 - asymmetrical)
|
Output
|
1 kV (Test Level 3 - symmetrical)
|
|
2 kV (Test Level 3 - asymmetrical)
|
Signal
|
4 kV (Test Level 4 - asymmetrical)
|
Comments
|
Criterion A
|
Conducted interference
|
EN 61000-4-6
|
I/O/S
|
asymmetrical
|
Frequency range
|
0.15 MHz ... 80 MHz
|
Voltage
|
10 V (Test Level 3)
|
Comments
|
Criterion A
|
Power frequency magnetic field
|
EN 61000-4-8
|
Frequency
|
16.7 Hz
|
|
50 Hz
|
|
60 Hz
|
Test field strength
|
100 A/m
|
Additional text
|
60 s
|
Comments
|
Criterion A
|
Frequency
|
50 Hz
|
|
60 Hz
|
Frequency range
|
50 Hz ... 60 Hz
|
Test field strength
|
1 kA/m
|
Additional text
|
3 s
|
Frequency
|
0 Hz
|
Test field strength
|
300 A/m
|
Additional text
|
DC, 60 s
|
Voltage dips
|
EN 61000-4-11
|
Voltage
|
400 V AC
|
Frequency
|
50 Hz
|
Voltage dip
|
70 %
|
Number of periods
|
0.5 / 1 / 25 / 30 periods
|
Additional text
|
Test Level 2
|
Comments
|
Criterion A: 0.5 / 1 periods Criterion B: 25 / 30 periods
|
Voltage dip
|
40 %
|
Number of periods
|
5 / 10 / 50 periods
|
Additional text
|
Test Level 2
|
Comments
|
Criterion B
|
|
Criterion A: 0.5 / 1 period Criterion B: 5 / 50 / 250 periods
|
Pulse-shape magnetic field
|
EN 61000-4-9
|
Test field strength
|
1000 A/m
|
Comments
|
Criterion A
|
Damped oscillating magnetic field
|
EN 61000-4-10
|
Test field strength
|
110 A/m
|
Test level 1
|
100 kHz
|
Test field strength
|
110 A/m
|
Test level 2
|
1 MHz
|
Comments
|
Criterion A
|
Attenuated sinusoidal oscillations (ring wave)
|
EN 61000-4-12
|
Input
|
2 kV (Test Level 4 - symmetrical)
|
|
4 kV (Test Level 4 - asymmetrical)
|
Comments
|
Criterion A
|
Asymmetrical conducted disturbance variables
|
EN 61000-4-16
|
Test level 1
|
15 Hz 150 Hz (Test Level 4)
|
Voltage
|
30 V 3 V
|
Test level 2
|
150 Hz 1.5 kHz (Test Level 4)
|
Voltage
|
3 V
|
Test level 3
|
1.5 kHz 15 kHz (Test Level 4)
|
Voltage
|
3 V 30 V
|
Test level 4
|
15 kHz 150 kHz (Test Level 4)
|
Voltage
|
30 V
|
Test level 5
|
16.7 Hz 50 Hz 60 Hz (Test Level 4)
|
Voltage
|
30 V (Permanent)
|
Test level 6
|
16.7 Hz 50 Hz 60 Hz (Test Level 4)
|
Voltage
|
300 V (1 s)
|
Comments
|
Criterion A
|
Attenuated oscillating wave
|
EN 61000-4-18
|
Input, output (test level 1)
|
100 kHz 1 MHz (Test Level 3 - symmetrical)
|
Voltage
|
1 kV
|
Input, output (test level 2)
|
10 MHz
|
Voltage
|
1 kV
|
Input, output (test level 3)
|
100 kHz 1 MHz (Test Level 3 - asymmetrical)
|
Voltage
|
2.5 kV
|
Signals (test level 1)
|
100 kHz 1 MHz (Test Level 3 - symmetrical)
|
Voltage
|
1 kV
|
Signals (test level 2)
|
100 kHz 1 MHz (Test Level 3 - asymmetrical)
|
Voltage
|
2.5 kV
|
Comments
|
Criterion A
|
Criterion A
|
Normal operating behavior within the specified limits.
|
Criterion B
|
Temporary impairment to operational behavior that is corrected by the device itself.
|
Criterion C
|
Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
|
Environmental Product Compliance
REACh SVHC
|
Lead 7439-92-1
|
China RoHS
|
Environmentally Friendly Use Period = 25;
|
|
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
|
ECLASS
ECLASS 10.0.1 |
27040701
|
ECLASS 11.0 |
27040701
|
ECLASS 5.1 |
27242213
|
ECLASS 6.0 |
27049005
|
ECLASS 9.0 |
27040701
|
ETIM
ETIM 6.0 |
EC002540
|
ETIM 7.0 |
EC002540
|
UNSPSC
UNSPSC 13.2 |
39121004
|
UNSPSC 18.0 |
39121004
|
UNSPSC 19.0 |
39121004
|
UNSPSC 20.0 |
39121004
|
UNSPSC 21.0 |
39121004
|
|
File description
|
File type
|
Download link
|
|
|
|
|
|
|
|
|