Image is illustrative
|
Redundancy Module UNO-DIODE/5-24DC/2X10/1X20, 1pcs/pck, Phoenix Code:
2905489
Price (indicative)
€59.00
/pc
(€73.16 /pc with VAT)
Manufacturer
:
Availability:
21 days
|
Weight:
0.21 kg/pc
|
Volume:
0.0004 m3/pc
|
|
|
|
|
Redundancy Module UNO-DIODE/5-24DC/2X10/1X20, 1pcs/pck, PhoenixDimensions
Width
|
22.5 mm
|
Height
|
90 mm
|
Depth
|
84 mm
|
Installation distance right/left
|
5 mm / 5 mm
|
Installation distance top/bottom
|
30 mm / 30 mm
|
Ambient conditions
Degree of protection
|
IP20
|
Inflammability class in acc. with UL 94 (housing / terminal blocks)
|
V0
|
Ambient temperature (operation)
|
-25 °C ... 70 °C (> 55 °C Derating: 2.5 %/K)
|
Ambient temperature (storage/transport)
|
-40 °C ... 85 °C
|
Max. permissible relative humidity (operation)
|
≤ 95 % (at 25 °C, non-condensing)
|
Climatic class
|
3K3 (in acc. with EN 60721)
|
Degree of pollution
|
2
|
Input data
Nominal input voltage range
|
5 V DC ... 24 V DC
|
Input voltage range
|
4.5 V DC ... 30 V DC
|
Nominal input current
|
2x 10 A (-25 °C ... 55 °C)
|
|
1x 20 A (-25 °C ... 55 °C)
|
|
2x 10 A (-25 °C ... 55 °C)
|
|
1x 20 A (-25 °C ... 55 °C)
|
Output data
Nominal output current (IN)
|
20 A
|
|
10 A
|
Derating
|
55 °C ... 70 °C (2.5%/K)
|
Power loss nominal load max.
|
5 W (IOUT = 10 A)
|
General
Net weight
|
0.2 kg
|
Efficiency
|
> 97 %
|
MTBF (IEC 61709, SN 29500)
|
|
|
> 60600000 h (40 °C)
|
|
|
Insulation voltage input/output
|
1 kV AC (type test)
|
|
0.5 kV AC (routine test)
|
Degree of protection
|
IP20
|
Protection class
|
III
|
Inflammability class in acc. with UL 94 (housing / terminal blocks)
|
V0
|
Housing material
|
Polycarbonate
|
Foot latch material
|
POM (Polyoxymethylen)
|
Mounting position
|
horizontal DIN rail NS 35, EN 60715
|
Assembly instructions
|
alignable: 0 mm horizontally, 30 mm vertically
|
Connection data, input
Connection method
|
Screw connection
|
Conductor cross section solid min.
|
0.2 mm²
|
Conductor cross section solid max.
|
2.5 mm²
|
Conductor cross section flexible min.
|
0.2 mm²
|
Conductor cross section flexible max.
|
2.5 mm²
|
Conductor cross section AWG min.
|
24
|
Conductor cross section AWG max.
|
14
|
Stripping length
|
8 mm
|
Screw thread
|
M3
|
Connection data, output
Connection method
|
Screw connection
|
Conductor cross section solid min.
|
0.2 mm²
|
Conductor cross section solid max.
|
2.5 mm²
|
Conductor cross section flexible min.
|
0.2 mm²
|
Conductor cross section flexible max.
|
2.5 mm²
|
Conductor cross section AWG min.
|
24
|
Conductor cross section AWG max.
|
14
|
Stripping length
|
8 mm
|
Screw thread
|
M3
|
Standards
EMC requirements for noise immunity
|
EN 61000-6-1
|
|
EN 61000-6-2
|
EMC requirements for noise emission
|
EN 61000-6-3
|
|
EN 61000-6-4
|
Standard - Electrical safety
|
IEC 62368-1 (SELV)
|
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations
|
EN 50178/VDE 0160 (PELV)
|
Standard – Safety extra-low voltage
|
IEC 62368-1 (SELV) und EN 60204-1 (PELV)
|
Conformance/approvals
UL approvals
|
UL/C-UL listed UL 508
|
|
UL/C-UL Recognized UL 60950-1
|
EMC data
Electromagnetic compatibility
|
Conformance with EMC Directive 2014/30/EU
|
Low Voltage Directive
|
Conformance with Low Voltage Directive 2014/35/EC
|
Electrostatic discharge
|
EN 61000-4-2
|
Contact discharge
|
4 kV (Test Level 3)
|
Discharge in air
|
8 kV (Test Level 3)
|
Electromagnetic HF field
|
EN 61000-4-3
|
Frequency range
|
80 MHz ... 1 GHz
|
Test field strength
|
10 V/m
|
Comments
|
Criterion A
|
Fast transients (burst)
|
EN 61000-4-4
|
Input
|
2 kV (Test Level 3 - asymmetrical)
|
Output
|
2 kV (Test Level 3 - asymmetrical)
|
Comments
|
Criterion B
|
Surge voltage load (surge)
|
EN 61000-4-5
|
Input
|
1 kV (Test Level 3 - symmetrical)
|
|
2 kV (Test Level 4 - asymmetrical)
|
Output
|
1 kV (Test Level 2 - symmetrical)
|
|
2 kV (Test Level 3 - asymmetrical)
|
Comments
|
Criterion B
|
Conducted interference
|
EN 61000-4-6
|
I/O/S
|
asymmetrical
|
Frequency range
|
0.15 MHz ... 80 MHz
|
Voltage
|
10 V (Test Level 3)
|
Comments
|
Criterion A
|
Voltage dips
|
EN 61000-4-11
|
Criterion A
|
Normal operating behavior within the specified limits.
|
Criterion B
|
Temporary impairment to operational behavior that is corrected by the device itself.
|
Environmental Product Compliance
REACh SVHC
|
Lead 7439-92-1
|
China RoHS
|
Environmentally Friendly Use Period = 25;
|
|
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
|
ECLASS
ECLASS 10.0.1 |
27371010
|
ECLASS 11.0 |
27371010
|
ECLASS 5.0 |
27371000
|
ECLASS 5.1 |
27371000
|
ECLASS 6.0 |
27371000
|
ECLASS 7.0 |
27371010
|
ECLASS 9.0 |
27371010
|
ETIM
ETIM 4.0 |
EC002540
|
ETIM 6.0 |
EC002540
|
ETIM 7.0 |
EC000683
|
UNSPSC
UNSPSC 13.2 |
39121004
|
UNSPSC 18.0 |
32151504
|
UNSPSC 19.0 |
32151504
|
UNSPSC 20.0 |
32151504
|
UNSPSC 21.0 |
32151504
|
|
File description
|