Image is illustrative
|
Simatic ET 200SP, Potential Distributor Module, PotDis terminal block, PotDis-TB-P1-R, 18x potential P1, Push-In terminals Code:
6ES7193-6TP00-0TP1
Price (indicative)
€17.80
/pc
(€22.07 /pc with VAT)
Manufacturer
:
|
Availability:
28 days
|
Weight:
0.062 kg/pc
|
Volume:
0.0001 m3/pc
|
|
|
|
|
Simatic ET 200SP, Potential Distributor Module, PotDis terminal block, PotDis-TB-P1-R, 18x potential P1, Push-In terminals, SiemensSIMATIC ET 200SP, Potential distributor module, PotDis terminal block, PotDis-TB-P1-R, 18 x potential P1, Push-In terminals Packaging Unit: 1 Piece,
| General information |
| Product type designation |
PotDis TB P1-R, PU 1 |
| Supply voltage |
| Rated value (DC) |
|
| ● For P1 and P2 bus |
48 V; max. |
| ● for process terminals |
48 V; max. |
| external protection for power supply lines |
Yes; 10 A miniature circuit breaker with type B or C tripping characteristic for the respective rated supply voltage |
| Current carrying capacity |
| up to 60 °C, max. |
10 A |
| For P1 and P2 bus, max. |
10 A |
| For AUX bus, max. |
10 A |
| For process terminals, max. |
10 A |
| Ambient conditions |
| Ambient temperature during operation |
| ● horizontal installation, min. |
0 °C; No condensation |
| ● horizontal installation, max. |
60 °C |
| ● vertical installation, min. |
0 °C; No condensation |
| ● vertical installation, max. |
50 °C |
| ● ceiling installation, min. |
0 °C; No condensation |
| ● ceiling installation, max. |
50 °C |
| ● floor installation, min. |
0 °C; No condensation |
| ● floor installation, max. |
50 °C |
| Altitude during operation relating to sea level |
| ● Ambient air temperature-barometric pressure-altitude |
On request: Ambient temperatures lower than 0 °C (without condensation) and/or installation altitudes greater than 2 000 m |
| Accessories |
| Color coding labels |
| ● for process terminals |
CC10, CC12 |
| Connection method |
| Terminals |
| ● Terminal type |
Push-in terminal |
| ● Conductor cross-section, min. |
0.14 mm²; 0.2 mm² without wire end ferrule |
| ● Conductor cross-section, max. |
2.5 mm²; 1.5 mm² with wire end ferrule |
| ● Number of process terminals to I/O module |
16 |
| ● Number of terminals to AUX bus |
0 |
| ● Number of add-on terminals |
0 |
| ● Number of terminals with connection to P1 and P2 bus |
2 |
| Dimensions |
| Width |
15 mm |
| Height |
74 mm |
| Depth |
34 mm |
| Weights |
| Weight, approx. |
24 g |
| last modified: |
11/10/2018 |
|
|
File description
|