Simatic S7-1500, Analog Output Module, 2AQ U/I ST, 16bit res., acc. 0.3%., 2-ch. in groups of 2, diagnostics, incl. push-in front connector, infeed element, shield bracket, shield terminal
Image is illustrative
Simatic S7-1500, Analog Output Module, 2AQ U/I ST, 16bit res., acc. 0.3%., 2-ch. in groups of 2, diagnostics, incl. push-in front connector, infeed element, shield bracket, shield terminal
Code: 6ES7532-5NB00-0AB0
Price (indicative)
€352.80  /pc
(€437.47 /pc with VAT)
Manufacturer :
Availability:
28 days
Weight:
0.3896 kg/pc
Volume:
0.0014 m3/pc
Quantity (pc):
Plus sign Minus sign
 

 

Simatic S7-1500, Analog Output Module, 2AQ U/I ST, 16bit res., acc. 0.3%., 2-ch. in groups of 2, diagnostics, incl. push-in front connector ^infeed element ^shield bracket ^shield terminal, Siemens

SIMATIC S7-1500, Analog output module AQ 2x U/I ST, 16 bit resolution, Accuracy 0.3%. 2 channels in groups of 2, diagnostics; Substitute value incl. push-in front connector, infeed element, shield bracket, shield terminal
General information
Product type designation AQ 2xU/I ST
HW functional status FS01
Firmware version V1.0.0
● FW update possible Yes
Product function
● I&M data Yes; I&M0 to I&M3
● Output range scalable No
Engineering with
● STEP 7 TIA Portal configurable/integrated as of version V13 / V13.0.2
● STEP 7 configurable/integrated as of version V5.5 SP3 / -
● PROFIBUS as of GSD version/GSD revision V1.0 / V5.1
● PROFINET as of GSD version/GSD revision V2.3 / -
Operating mode
● Oversampling No
● MSO Yes
CiR – Configuration in RUN
Reparameterization possible in RUN Yes
Calibration possible in RUN Yes
Supply voltage
Type of supply voltage DC
Rated value (DC) 24 V
permissible range, lower limit (DC) 20.4 V
permissible range, upper limit (DC) 28.8 V
Reverse polarity protection Yes
Input current
Current consumption, max. 110 mA; with 24 V DC supply
Power
Power available from the backplane bus 0.65 W
Power loss
Power loss, typ. 2.7 W
Analog outputs
Number of analog outputs 2
Voltage output, short-circuit protection Yes
Voltage output, short-circuit current, max. 24 mA
Current output, no-load voltage, max. 22 V
Cycle time (all channels), min. 3.2 ms; independent of number of activated channels
Output ranges, voltage
● 0 to 10 V Yes
● 1 V to 5 V Yes
● -5 V to +5 V No
● -10 V to +10 V Yes
Output ranges, current
● 0 to 20 mA Yes
● -20 mA to +20 mA Yes
● 4 mA to 20 mA Yes
Connection of actuators
● for voltage output two-wire connection Yes
● for voltage output four-wire connection Yes
● for current output two-wire connection Yes
Load impedance (in rated range of output)
● with voltage outputs, min. 1 kΩ; 0.5 kOhm at 1 to 5 V
● with voltage outputs, capacitive load, max. 1 µF
● with current outputs, max. 750 Ω
● with current outputs, inductive load, max. 10 mH
Cable length
● shielded, max. 800 m; for current, 200 m for voltage
Analog value generation for the outputs
Integration and conversion time/resolution per channel
● Resolution with overrange (bit including sign), max. 16 bit
● Conversion time (per channel) 0.5 ms
Settling time
● for resistive load 1.5 ms
● for capacitive load 2.5 ms
● for inductive load 2.5 ms
Errors/accuracies
Output ripple (relative to output range, bandwidth 0 to 50 kHz), (+/-) 0.02 %
Linearity error (relative to output range), (+/-) 0.15 %
Temperature error (relative to output range), (+/-) 0.002 %/K
Crosstalk between the outputs, max. -100 dB
Repeat accuracy in steady state at 25 °C (relative to output range), (+/-) 0.05 %
Operational error limit in overall temperature range
● Voltage, relative to output range, (+/-) 0.3 %
● Current, relative to output range, (+/-) 0.3 %
Basic error limit (operational limit at 25 °C)
● Voltage, relative to output range, (+/-) 0.2 %
● Current, relative to output range, (+/-) 0.2 %
Isochronous mode
Isochronous operation (application synchronized up to terminal) No
Interrupts/diagnostics/status information
Diagnostics function Yes
Substitute values connectable Yes
Alarms
● Diagnostic alarm Yes
Diagnostic messages
● Monitoring the supply voltage Yes
● Wire-break Yes; Only for output type "current"
● Short-circuit Yes; Only for output type "voltage"
● Overflow/underflow Yes
Diagnostics indication LED
● RUN LED Yes; Green LED
● ERROR LED Yes; Red LED
● Monitoring of the supply voltage (PWR-LED) Yes; Green LED
● Channel status display Yes; Green LED
● for channel diagnostics Yes; Red LED
● for module diagnostics Yes; Red LED
Potential separation
Potential separation channels
● between the channels No
● between the channels, in groups of 2
● between the channels and backplane bus Yes
● Between the channels and load voltage L+ Yes
Permissible potential difference
between S- and MANA (UCM) 8 V DC
Isolation
Isolation tested with 707 V DC (type test)
Ambient conditions
Ambient temperature during operation
● horizontal installation, min. 0 °C
● horizontal installation, max. 60 °C
● vertical installation, min. 0 °C
● vertical installation, max. 40 °C
Decentralized operation
Prioritized startup No
Dimensions
Width 25 mm
Height 147 mm
Depth 129 mm
Weights
Weight, approx. 200 g
Other
Note: Supplied incl. 40-pole push-in front connectors